MB Slab System
The smarter approach to slab reinforcement

The typical way to control cracks in slabs-on-ground is to employ contraction joints with sufficient depth and proper spacing to prevent mid-panel cracking. The more joints required, the greater the impact on the designer’s flexibility, the contractor's time and labor, slab aesthetics, as well as the owner’s long-term maintenance costs. Now, there’s a better, more advanced solution.
MB Slab System Introduction
The MB Slab System is designed to reduce joints in slabs-on-ground

Utilizing the synergy between shrinkage-reducing technologies and fiber reinforcement, the MB Slab System offers a significant improvement over traditional slab construction. It allows joints to be spaced significantly further apart, or in some cases, eliminated altogether.
Who Benefits?
Producers
Increase product offerings with fiber solutions that help meet the evolving needs of customers.
Contractors
Accelerate construction timelines with fiber-reinforced solutions that reduce saw-cut joints and deliver significant installation cost savings.
Architects
Achieve greater design and usage flexibility with fiber solutions that enhance aesthetics and support a reduced environmental footprint.
Owners
Fiber-reinforced solutions promote sustainability, lower lifecycle costs, and help deliver projects on time and on budget.

Our expertise is part of the mix
The MB Slab System is more than the products it contains. It’s a complete design and construction strategy that makes concrete capable of doing more than previously thought possible. That’s the benefit of working with the Master Builders Solutions team. To get started, contact a representative today.
Testimonials
Project Profiles
Million Air
Medford, OR
Our extended joint spacing solution eliminated rebar and over 6,800 feet of joints, cutting construction costs and reducing long-term maintenance.
Palo Verde Wastewater Reclamation Facility
Maricopa, AZ
This award-winning fiber-reinforced system eliminated rebar and joints, cut construction time by five days, and enabled monolithic slab placement.
Viking Group, Inc.
Michigan
Our fiber-reinforced concrete solutions reduced maintenance costs in manufacturing and provided polished, aesthetically pleasing floors in the office areas.
RA Libs Inc.
Sellersburg, IN
RA Libs showcased the MB Slab System’s joint-eliminating, crack-reducing benefits and its polished aesthetic for office floors.
Pharmaceutical Facility
Michigan
Our slab-on-ground solution reduced construction time and labor, while providing tight joints, minimal floor curl, and superior durability, minimizing equipment wear.
Klein Farms
Seymore, IL
Our MB Slab System eliminated saw-cut joints, protected the radiant heat system, and used crack-reducing admixtures to improve durability and workability.